A Proactive Approach to Maintenance
The G2F approach to maintenance replaces the 'failure reactive' philosophy with 'failure proactive' by implementing corrective measures to avoid problems you will eventually encounter. G2F is a low cost 'Proactive' maintenance asset management tool. It lowers long-term maintenances costs, while providing short-term savings on oil, standard Filters, downtime, and waste oil. This offers a relatively quick return on the capital investment.
Some common engine problems can help be identified by the condition of the G2F element.
A Normal Element - Changed at proper
interval, element removed high
concentrations of soot/carbon, indicating
normal engine wear.
B Metal Dust Particles Present - Indicating
engine overload. Wear is taking place in
metal component. Investigate source
immediately.
C Soot/Carbon Overload - Higher than normal
levels accumulated indicating possible
overheating, engine overload, coolant
system malfunction, or due to extreme
element extension intervals.
D Fuel Dilution - Element will become dry and turn grey in colour, indicating fuel is present
in the oil.
E Coolant Leak - Element is cracked, spongy,
and shrunken, indicating water is present in
the oil. |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
|
|